What size generator do you need? Check off your appliances and get an instant wattage calculation — running watts, starting watts, and recommended generator size included.
Choosing the right generator size comes down to two numbers: running watts and starting watts. Running watts is the continuous power draw of all your appliances added together. Starting watts accounts for the extra surge of power that motors (refrigerators, air conditioners, pumps) need for a fraction of a second when they first kick on. A generator must handle both.
Most electric motors require 2–3 times their normal running wattage to get started. This surge only lasts for a second or two, but if your generator cannot supply it, the motor will stall or trip a breaker. The peak demand on your generator at any moment is the sum of all running loads plus the starting surge of whichever appliance is starting at that moment. This calculator uses the single largest starting surge (a conservative and common industry approach), since it is unlikely that two large motors would start simultaneously.
The 20% headroom rule is important: running a generator at 100% capacity shortens its life and leaves no buffer for a second appliance starting. Most generator manufacturers recommend staying at or below 80% of rated capacity during normal operation.
| Generator Size | Typical Use Case | Can Usually Power |
|---|---|---|
| 1,000–2,000 W | Camping / tailgate | Phone chargers, laptops, small appliances, a few lights |
| 3,000 W | Basic home backup | Refrigerator, lights, TV, phone charging, sump pump (small) |
| 5,000 W | Essential home circuits | Refrigerator, freezer, sump pump, well pump, lights, fans |
| 7,500 W | Comfortable home backup | All of the above + window AC or small central AC, microwave |
| 10,000 W | Most of the home | Central AC (up to 3 tons), most kitchen appliances, multiple rooms |
| 12,000–15,000 W | Whole-home portable / large standby | Large central AC, electric water heater, washer, most appliances |
| 20,000+ W | Whole-home standby | Full home including electric dryer, large AC, electric range |
Portable generators run on gasoline (or dual fuel) and must be started manually and positioned outdoors. They are the most common and affordable option for occasional power outages. Sizes range from 1,000 W to 17,500 W. They require extension cords or a transfer switch to power your home circuits safely.
Standby generators are permanently installed and connect to your home's electrical panel via an automatic transfer switch (ATS). They run on natural gas or propane so they never run out of fuel. They start automatically within seconds of a power outage. Sizes typically start at 7,000 W and go up to 20,000 W or more for whole-home coverage. Cost is significantly higher ($3,000–$15,000+ installed) but convenience is unmatched.
Inverter generators produce clean, stable power (low total harmonic distortion) that is safe for sensitive electronics like laptops, medical equipment, and smart appliances. They are quieter, more fuel-efficient at partial load, and more portable than conventional generators. Their main limitation is size — most inverter generators top out around 7,000 W, making them best suited for essential loads rather than whole-home backup.
| Fuel Type | Pros | Cons |
|---|---|---|
| Gasoline | Widely available, affordable generators, high power density | Short shelf life (30–90 days), price-volatile, can be hard to find during emergencies |
| Propane | Indefinite shelf life, burns cleaner, can store large tanks on-site | Lower energy density (burns more fuel per kWh), tank infrastructure cost |
| Dual Fuel | Flexibility to use gasoline or propane, best of both worlds | Slight power reduction on propane, slightly higher unit cost |
| Natural Gas | Unlimited supply (utility line), never runs dry, clean burning | Requires permanent plumbing, power may be interrupted in major disasters |
| Diesel | Longest-lasting fuel, very efficient at high load, long engine life | More expensive units, louder, diesel fuel gels in very cold weather |
The most common mistake when sizing a generator is ignoring starting watts. A central air conditioner rated at 3,500 running watts may draw 7,000 watts for the first second or two when the compressor starts. If your generator is rated at 5,000 watts, it will struggle or stall every time the AC kicks on — even though 3,500 W is well within its rated capacity. This is why this calculator calculates peak load (running + largest starting surge) and recommends a generator large enough to handle it comfortably.